Title of article :
Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heating system fitted with regularly spaced twisted tape with rod and spacer
Author/Authors :
Ananth، نويسنده , , J. and Jaisankar، نويسنده , , S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
207
To page :
213
Abstract :
Experimental investigation of heat transfer and friction factor characteristics of thermosyphon solar water heater with full length helical twist of twist ratio 3, twist with rod and spacer of lengths 125, 250 and 500 mm has been studied. The experimental data for plain tube collector has been compared with fundamental equation falls within the acceptable limits for Nusselt number and friction factor. Findings shows that the Nusselt number decreases with increase in rod and spacer length and the pressure drop increases with decrease in rod and spacer length when compared with full length twist. Further the correlations developed for friction factor and Nusselt number has predicted the experimental data satisfactorily. The heat transfer enhancement in twist fitted with rod is found to be superior when compared with twist fitted with spacer.
Keywords :
Swirl flow , Helical twisted tapes , Friction factor , Nusselt number , thermosyphon , Rod and spacer