Title of article
Improvement of buildings energy efficiency: Comparison, operability and results of commissioning tools
Author/Authors
Ginestet، نويسنده , , S. and Marchio، نويسنده , , D. and Morisot، نويسنده , , O.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
9
From page
368
To page
376
Abstract
Mainly published to reduce greenhouse gases emissions, new building regulations, leads to a constant improvement of building components such as building envelopes and static insulation. Although, the effectiveness and the behaviour of the air-conditioning plants, validated by commissioning procedures, affect greatly the energy needs in buildings, through ventilation requirements. The main work of Annex 40 of the International Agency of the Energy reports on “Commissioning of Building HVAC systems for Improved Energy Performance”. The retro- and on-going commissioning of existing buildings HVAC systems can be achieved using many tools. In this annex, we focus on three which have several objectives and intervene in different phases of the commissioning process. One leads to the detection of faults whereas the others contribute to energy consumption evaluation. This paper presents a critical analysis of the various tools used and evaluates the potential of each tool in the commissioning phases under consideration, in order to determine the most convenient ones for the project in question. The work presented in this paper allows providing a helpful advice to the energy service company or to the technical and research institutes to determine the most adequate tool in terms of number of potential detected faults, precision in energy savings evaluation, and end-user’s assessment. A critical analysis is presented to evaluate three of these tools and apply them to a real building. It appears clearly that the PECI Guide, developed for new construction, is very useful in retro-commissioning procedures. Moreover, Emma-CTA and its new versions (CITE-AHU, etc.) represent excellent fault detection tools and diagnosis tools of AHU. For energy savings, the IMPVP tends to become an international standard in measurement and verifications procedures for the ESCO, in order to evaluate energy savings following retrofit. The main issue of our work is to evaluate the operability, potential, time consumed, and results of these tools when used by the HVAC operation staff.
Keywords
Commissioning tools , Energy efficiency , Operability on existing buildings
Journal title
Energy Conversion and Management
Serial Year
2013
Journal title
Energy Conversion and Management
Record number
2337169
Link To Document