Title of article :
Performance analysis of photovoltaic thermal (PVT) water collectors
Author/Authors :
Fudholi، نويسنده , , Ahmad and Sopian، نويسنده , , Kamaruzzaman and Yazdi، نويسنده , , Mohammad H. and Ruslan، نويسنده , , Mohd Hafidz and Ibrahim، نويسنده , , Adnan and Kazem، نويسنده , , Hussein A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
11
From page :
641
To page :
651
Abstract :
The electrical and thermal performances of photovoltaic thermal (PVT) water collectors were determined under 500–800 W/m2 solar radiation levels. At each solar radiation level, mass flow rates ranging from 0.011 kg/s to 0.041 kg/s were introduced. The PVT collectors were tested with respect to PV efficiency, thermal efficiency, and a combination of both (PVT efficiency). The results show that the spiral flow absorber exhibited the highest performance at a solar radiation level of 800 W/m2 and mass flow rate of 0.041 kg/s. This absorber produced a PVT efficiency of 68.4%, a PV efficiency of 13.8%, and a thermal efficiency of 54.6%. It also produced a primary-energy saving efficiency ranging from 79% to 91% at a mass flow rate of 0.011–0.041 kg/s.
Keywords :
Primary-energy saving efficiency , Electrical performance , Thermal Performance , Photovoltaic thermal (PVT) , PVT performance
Journal title :
Energy Conversion and Management
Serial Year :
2014
Journal title :
Energy Conversion and Management
Record number :
2337437
Link To Document :
بازگشت