• Title of article

    Numerical and experimental evaluation of fly ash collection efficiency in electrostatic precipitators

  • Author/Authors

    Al-Hamouz، نويسنده , , Zakariya، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    11
  • From page
    487
  • To page
    497
  • Abstract
    This paper evaluates experimentally and numerically the influence of different geometrical and operating parameters of a single stage wire-duct electrostatic precipitators (WDEP) on its fly ash collection efficiency. The governing equations are solved under dust loading conditions using the finite element method (FEM) and a modified method of characteristics (MMC). In addition, a proto-type design that represents a WDEP was successfully designed and fabricated at the research institute of KFUPM (RI-KFUPM). The experiments were carried out under laboratory conditions where the WDEP was made of Plexiglas with a length of 2 m, height of 1 m, wire-to-collecting plate spacing of 0.2–0.3 m, and an inter-electrode (wire-to-wire) spacing of 0.16–0.21 m. Smoke of fired coal was used as a source of seed particles of PM10 category (with 75–80% of particles lying below 10 μ m ). An indication of the effectiveness of the numerical approach was carried out through a comparison of computed results as well as presently and previously obtained experimental data.
  • Keywords
    Electrostatics , corona , Fly ash , Collection efficiency , Precipitators
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2014
  • Journal title
    Energy Conversion and Management
  • Record number