Title of article
Design and operation of a tri-generation system for a station in China
Author/Authors
Zhao، نويسنده , , Xiling and Fu، نويسنده , , Lin and Li، نويسنده , , Feng and Liu، نويسنده , , Hua، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
7
From page
391
To page
397
Abstract
Tri-generation usually refers to the simultaneous production of power, heating and cooling. Tri-generation can be regarded as a high-efficiency technology, provided that a large proportion of the energy rejected by the prime mover is used. In this paper, the design and operation of a tri-generation system for a railway station was investigated.
stem is composed of the internal combustion engine (ICE), absorption heat pump (AHP), heat exchanger (HE), and other facilities. The system was built and operated in 2011, and the energy efficiency level was analyzed. The results indicated that the calculated maximum comprehensive energy efficiency (CEE) was 94.94% in the winter and 84.33% in the summer; with the calculated maximum exergy efficiency is 38.01% in the winter and 36.01% in the summer. The primary energy saving (PES) of the system was 32.2% in the winter and 4.9% in the summer. The system could therefore be regarded as high efficiency tri-generation. The recovered year of the increased investment was 5.47 year compared with the reference system. These results could serve as a reference for designing or evaluating tri-generation systems.
Keywords
absorption heat pump , Condensation heat recovery , Energy and exergy analysis Ccw , Tri-generation
Journal title
Energy Conversion and Management
Serial Year
2014
Journal title
Energy Conversion and Management
Record number
2337593
Link To Document