• Title of article

    Thermal performance of direct-flow coaxial evacuated-tube solar collectors with and without a heat shield

  • Author/Authors

    Zhang، نويسنده , , Xinyu and You، نويسنده , , Shijun and Ge، نويسنده , , Hongchuan and Gao، نويسنده , , Yan and Xu، نويسنده , , Wei and Wang، نويسنده , , Min and He، نويسنده , , Tao and Zheng، نويسنده , , Xuejing، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    8
  • From page
    80
  • To page
    87
  • Abstract
    Experimental performance evaluation and comparative analyses based on heat extraction of direct-flow coaxial evacuated-tube solar collectors with and without heat shields are presented in this paper. A test system to evaluate the thermal performance of medium-temperature solar collectors was developed. The experimental analysis shows the evacuated-tube solar collector performed better with a heat shield, especially at higher working temperatures. The collection efficiency of the solar collector with a heat shield was 54.70% at the highest inlet temperature of 123.9 °C during the test period, which is 31.49% higher than for the solar collector without a heat shield. The calculated heat-loss coefficient for the evacuated-tube solar collector with a heat shield was 1.86 W/(m2 K), which is an improvement of 50.80% compared with that of the collector without a heat shield.
  • Keywords
    Thermal performance improvement , Evacuated-tube solar collector , Solar energy , Heat shield , Direct flow
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2014
  • Journal title
    Energy Conversion and Management
  • Record number