Title of article :
Failure analysis of a stainless steel pipeline
Author/Authors :
Suresh Kumar، نويسنده , , M. and Sujata، نويسنده , , M. A. Venkataswamy، نويسنده , , M.A. and Bhaumik، نويسنده , , S.K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
8
From page :
497
To page :
504
Abstract :
In this study, the failure of a stainless steel (SS) pipeline supplying hydrogen to a hydro cracking reactor of a petrochemical industry is investigated. Leakage was observed in the pipeline during operation. Study revealed that the failure was by chloride stress corrosion cracking. The source of chlorine was found to be the glass wool that was wrapped on the pipeline for thermal insulation purpose. Use of SS foil beneath the thermal insulator facilitated condensation of chloride ions. The protective SS foil was destroyed by pitting corrosion followed by which the pipeline failed by stress corrosion cracking. A detailed analysis of the failure is presented in this paper.
Keywords :
Corrosion under insulation (CUI) , Stainless steel pipeline , Pitting corrosion , Chloride stress corrosion cracking
Journal title :
Engineering Failure Analysis
Serial Year :
2008
Journal title :
Engineering Failure Analysis
Record number :
2338094
Link To Document :
بازگشت