Title of article :
Failure analysis and redesign of a helix upper dispenser
Author/Authors :
Woo، نويسنده , , Seong-woo and Pecht، نويسنده , , Michael، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
12
From page :
642
To page :
653
Abstract :
Failure analysis was conducted on a fractured helix upper dispenser for a side-by-side refrigerator with ice dispenser system. To reproduce the failure modes and mechanisms causing the fracture, a tailored set of accelerated life testing were applied to sample dispensers. Using bond graphs and state equations, key noise parameters in the assembly, including a variety of mechanical loads, were analyzed. The failure modes and mechanisms found experimentally were identical with those of the failed sample. To correct the problem, the key controllable design parameters of the helix upper dispenser were modified by eliminating gaps and enforcing ribs. The B1 life of the new design is now guaranteed to be over 14 years with a yearly failure rate of 0.021%.
Keywords :
Reliability design , load analysis , Accelerated life testing
Journal title :
Engineering Failure Analysis
Serial Year :
2008
Journal title :
Engineering Failure Analysis
Record number :
2338119
Link To Document :
بازگشت