Failure investigation on rear water wall tube of boiler
Author/Authors
Ahmad، نويسنده , , J. and Purbolaksono، نويسنده , , J. and Beng، نويسنده , , L.C. and Rashid، نويسنده , , A.Z. and Khinani، نويسنده , , A. and Ali، نويسنده , , A.A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
8
From page
2325
To page
2332
Abstract
This paper presents failure investigation on the SA210-A1 rear water wall tube by visual site inspection, tube wall thickness measurements and microscopic examination. The rear water wall tube has failed with wide open burst and was situated at the boiler nose lower bent region. On-site wall thickness measurements were performed on all the rear water wall tubes located at the same level of the ruptured tube. The tubes were observed to have experienced significant wall thinning. Microscopic examinations on the failed rupture region and some distance away region of the as-received tubes are also conducted in order to support in determining the failure mechanism and failure root cause. Failure mechanisms are discussed and the findings obtained from the site inspection, wall thickness measurements, microscopic examinations and creep analyses may finally reveal the failure mechanism and main root cause of the failure. The failure mechanism is identified as a result of the combination of the significant localized wall thinning of the rear water wall tube due to fly-ash erosion and a thermally activated process of creep problem due to increasing of temperatures.
Keywords
Failure analysis , Rear water wall tube , Fly-ash , WALL THINNING , visual inspection
Journal title
Engineering Failure Analysis
Serial Year
2009
Journal title
Engineering Failure Analysis
Record number
2338711
Link To Document