• Title of article

    Dynamic fracture toughness of a high strength armor steel

  • Author/Authors

    Gلlvez، نويسنده , , F. and Cendَn، نويسنده , , D. and Garcيa، نويسنده , , N. and Enfedaque، نويسنده , , A. and Sلnchez-Gلlvez، نويسنده , , V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    9
  • From page
    2567
  • To page
    2575
  • Abstract
    This paper summarizes the results of a research being carried out to determine fracture behavior both in static and dynamic conditions of high strength armor steel Armox500T. In this research, notched specimens were cut to be tested in three-point bending test. Specimens were pre-cracked by flexural fatigue. Thereafter, some specimens were tested in bending up to rupture to determine the static fracture toughness KIC. To obtain fracture toughness in dynamic conditions, a split Hopkinson bar modified to perform three-point bending tests was used. In this device, displacements and velocities of the specimen were measured, as well as the rupture time by means of fracture detection sensors, glued to the specimens. After that, a numerical simulation of the test was performed by using LS DYNA hydrocode, obtaining stresses and strain histories around the crack tip. From these results, the stress intensity factor history was derived. By using the rupture time, measured by the sensors, the value of the fracture toughness computed was unrealistic. Therefore, the use of a numerical procedure to obtain the rupture time was decided, by comparing experimental results of velocities at the transmission bar with numerical results obtained with several rupture times. With this procedure, the computation of dynamic fracture toughness was possible. The method shows that the measurement of the dynamic fracture toughness is possible without the needs of using crack sensors or strain gauges. It can be observed that fracture toughness of this steel under static and dynamic conditions is quite similar.
  • Keywords
    Hopkinson Bar , armour steel , Dynamic fracture , high strain rate , Bending test
  • Journal title
    Engineering Failure Analysis
  • Serial Year
    2009
  • Journal title
    Engineering Failure Analysis
  • Record number

    2338759