• Title of article

    Comparative study of a novel liquid–vapour separator incorporated gravitational loop heat pipe against the conventional gravitational straight and loop heat pipes – Part II: Experimental testing and simulation model validation

  • Author/Authors

    Zhang، نويسنده , , Xingxing and Shen، نويسنده , , Jingchun and He، نويسنده , , Wei and Xu، نويسنده , , Peng and Zhao، نويسنده , , Xudong and Tan، نويسنده , , Junyi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2015
  • Pages
    11
  • From page
    228
  • To page
    238
  • Abstract
    Aim of the paper is to report the experimental study of a novel liquid–vapour separator incorporated gravity-assisted loop heat pipe (GALHP) (T1), against the conventional GALHP (T2) and a gravitational straight heat pipe (T3). Based on the results derived from the theoretical analyses and computer modelling, three prototype heat pipes, one for each type, were designed, constructed and tested to characterise their thermal performance under a series of operational conditions. By using the experimental data, the computer simulation model reported in the authors’ previous paper was examined and analysed, indicating that the model could achieve a reasonable accuracy in predicting the thermal performance of the three heat pipes. Under the specifically defined testing condition, T1 has more evenly distributed axial temperature profile than the other two heat pipes (T2 and T3). The start-up timings for T1, T2 and T3 were 410 s, 1400 s and 390 s respectively, indicating that the heat transfer within T2 was affected by the larger evaporator dry-out surface area and restricted evaporation area. The overall thermal resistance of T1 was 0.11 °C/W, which was around 20% and 50% that of T2 and T3. The tested effective thermal conductivity in T1 was 29,968 W/°C m, which was 296% and 648% that of T2 and T3, and 7492% that of a standard copper rod. It is therefore concluded that the novel heat pipe (T1) could achieve a significantly enhanced heat transport effect, relative to T2, T3 and standard cooper rod. The experimental results derived from this research enabled characterisation of the thermal performance of T1, relative to other heat pipes, and validation of the developed computer simulation model derived from the authors’ previous research. These two parts researches in combination will enable design, optimisation and analyse of such a new GALHP, thus promoting its wide application and achieving efficient thermal management.
  • Keywords
    thermal conductivity , Model validation , start up , heat pipe , Experiment
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2015
  • Journal title
    Energy Conversion and Management
  • Record number