• Title of article

    Prediction of ammonium salt deposition in hydroprocessing air cooler tubes

  • Author/Authors

    Ou، نويسنده , , Guofu and Jin، نويسنده , , Haozhe and Xie، نويسنده , , Haoping and Cao، نويسنده , , Jing and Qiu، نويسنده , , Jie، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    1458
  • To page
    1464
  • Abstract
    Corrosion by wet ammonium salt is one of the main causes to the failure of reactor effluent air cooler (REAC) tubes. Based on a failure case, this paper presents the dynamic process of ammonium chloride (NH4Cl) deposition. A finite element method was used for the numerical simulation of the flow field, temperature field and concentration field to analysis this deposition process. The effect of velocity on ammonium salt deposition was also analyzed by the simulation. Based on the study, we suggest that the process of ammonium salt deposition may be affected by multi-physical field coupling. Higher temperature gradient exists between the fluid and the wall surface. As velocity increases, the amount of deposited salt reduces while the distance of the position with max amount to REAC inlet increases. Compared with actual failure instances, this method can be used effectively in predicting the relative severity of ammonium salt corrosion in REAC tubes.
  • Keywords
    Ammonium salt , Multi-physical field , Deposition , Numerical simulation
  • Journal title
    Engineering Failure Analysis
  • Serial Year
    2011
  • Journal title
    Engineering Failure Analysis
  • Record number