Title of article :
Corrosion failure analysis of high strength grade super 13Cr-110 tubing string
Author/Authors :
Zhu، نويسنده , , S.D. and Wei، نويسنده , , J.F. and Cai، نويسنده , , R. and Bai، نويسنده , , Z.Q. and Zhou، نويسنده , , G.S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
The main reasons for corrosion failure of super 13Cr-110 tubing and couplings have been proposed based on the analysis techniques of Optical Microscopy (OM), Scanning Electron Microscope (SEM), Energy Dispersive Spectrometer (EDS) and X-ray Diffraction (XRD). The results show that the composition, structure and mechanical properties of the tubing and the coupling were all in accordance with the corresponding parameter requirements of API Spec 5CT standards. Furthermore, corrosion occurring in the inner wall of joint was caused by the combined impacts of CO2 corrosion, acid corrosion, erosion corrosion, and crevice corrosion, meanwhile, the synergistic effects of crevice corrosion, and sulfate-reducing bacteria (SRB) corrosion resulted in corrosion occurring in the outer wall of the tubing and the coupling. Finally, to check the quality of the tubing string before well completion, increase torque, install a centralizer, and add bactericide and inhibitor were advised to prevent the types of corrosion failure from taking place.
Keywords :
Erosion corrosion , SRB corrosion , Failure analysis , Super 13Cr-110 , Crevice corrosion
Journal title :
Engineering Failure Analysis
Journal title :
Engineering Failure Analysis