• Title of article

    Failure of pyrolysis coils coated with anit-coking film in an ethylene cracking plant

  • Author/Authors

    Goswami، نويسنده , , A. and Kumar، نويسنده , , S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    7
  • From page
    181
  • To page
    187
  • Abstract
    This paper presents a specific kind of failure in ethylene cracking coils coated with anti-coking film. It investigates a case in which the coils made of 35Cr 45Ni high temperature alloy failed within two years of operation. The damage occurred due to heavy oxidation in localized regions of the coil resulting in the formation of blisters, which eventually failed by cracking. The mechanism involved was determined by studying the oxidized samples under a scanning electron microscope with an energy dispersive system and is attributed to the presence of rare earth metals in the anti-coking film and inherent casting defects in the base alloy. The cerium present in the anti-coking film diffused preferentially to a defect site in the parent alloy thereby resulting in its segregation which further led to embrittlement.
  • Keywords
    Oxidation , rare earth elements , Anti-coking film