Title of article :
Evaluation of a thermal criterion for an engineered barrier system
Author/Authors :
Imbert، نويسنده , , C. and Olchitzky، نويسنده , , E. and Lassabatère، نويسنده , , T. and Dangla، نويسنده , , P. and Courtois، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
The retention curve of French FoCa compacted clay has been determined at 20, 50 and 80 °C. A saline saturated solution has been used to control the suction. The temperature, up to 80 °C, has no influence on the e(Pc) curve. On the other hand, the water content and the liquid saturation degree are lower at 50 or 80 °C than at 20 °C. A model is proposed to take into account the influence of the temperature, in the framework of Biotʹs theory.
od to determine the liquid permeability of an unsaturated porous media is proposed. It is based on an analytical solution and on an experimental survey of the transient phase of desorption. This method has been applied to the compacted FoCa clay, at 20 °C. It is easy to implement and efficient. The permeability of FoCa clay has been determined for a large range of suctions.
Keywords :
Swelling clay , FoCa clay , Bentonite , Temperature , Modelling , Capillary curves , Relative liquid permeability , analytical solution
Journal title :
Engineering Geology
Journal title :
Engineering Geology