Title of article
Causes of scatter in high rate fracture testing of polymers
Author/Authors
Agnelli، نويسنده , , S. and Horsfall، نويسنده , , I.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
8
From page
59
To page
66
Abstract
A method based on the measurement of failure time is being developed by the European Structural Integrity Society to determine high rate fracture toughness of polymers. The test method appears reasonably straightforward but produced unacceptably high scatter, due to failure time data scatter. In this work an experimentally based sensitivity study was performed by fracture tests at 1 ms−1 in order to determine the causes of scatter and to seek to improve the test protocol. No single cause of scatter was identified but the quality and repeatability of the notching technique was identified as a major contributor.
Keywords
impact fracture , Polymers , Toughness testing , Dynamic fracture
Journal title
ENGINEERING FRACTURE MECHANICS
Serial Year
2013
Journal title
ENGINEERING FRACTURE MECHANICS
Record number
2343828
Link To Document