• Title of article

    Effect of seismic isolation on the Tokamak in ITER

  • Author/Authors

    Tsunematsu، نويسنده , , T. and NAMBA، نويسنده , , H. and Akutsu، نويسنده , , Y. and Ohkawa، نويسنده , , Y. and Yagenji، نويسنده , , A. and Takeda، نويسنده , , Peter M. and Yajima، نويسنده , , K. and Nitta، نويسنده , , Y. and Kobayashi، نويسنده , , K. and Maeda، نويسنده , , I. and Takenaka، نويسنده , , Y.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    6
  • From page
    415
  • To page
    420
  • Abstract
    The support structure of the International Thermonuclear Experimental Reactor (ITER) is suggested to have appropriate stiffness that accommodates both thermal distortion of the system and a maximum ground acceleration of 0.2 G (1 G=9.8 m s−1) due to earthquakes. For a site with earthquakes more severe than 0.2 G, the seismic isolation design is a possible candidate for keeping the seismic input low enough. The present design of ITER assumes that only the Tokamak pit portion is isolated, due to the whole building being very large and complex. In this study, dynamic analyses of the whole Tokamak building with a base-isolated Tokamak pit were carried out, and the effect of the isolation of the pit structure was evaluated. As a possible input level, a 0.4 G maximum ground acceleration was assumed. Particular attention was paid to the relative displacement between isolated and non-isolated portions, due to the smaller relative displacement being desirable for the design of pipes across the isolation gap.
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    1998
  • Journal title
    Fusion Engineering and Design
  • Record number

    2350057