• Title of article

    New electron cyclotron emission diagnostics for the TEXTOR tokamak

  • Author/Authors

    van de Pol، نويسنده , , M.J and Udintsev، نويسنده , , V.S and Donné، نويسنده , , A.J.H and Krنmer-Flecken، نويسنده , , A and Deng، نويسنده , , B.H and Domier، نويسنده , , C.W and Luhmann Jr.، نويسنده , , N.C and Park، نويسنده , , H.K and Mazzucato، نويسنده , , E، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    7
  • From page
    177
  • To page
    183
  • Abstract
    Three new electron cyclotron emission (ECE) systems will be installed at TEXTOR: a 16-channel ECE imaging diagnostic, a 16-channel radiometer, with frequency-tunable local oscillators in the second down-conversion step, and a 4-channel second harmonic radiometer that will be used in combination with an already available third harmonic system. The new diagnostics, in combination with the systems already present at TEXTOR offer unique measurement capabilities. In this paper, all the three systems along with their diagnostic potential will be described.
  • Keywords
    Radiometer , Electron cyclotron emission , TEXTOR