Title of article
Safety classification of the ITER fusion power shutdown system and resulting safety requirements
Author/Authors
Costa، نويسنده , , M، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
14
From page
361
To page
374
Abstract
The paper presents an application of a new safety classification approach, which is founded upon the Lines of Defence (LODs) method for the organisation of the plant safety architecture needed to assure the confinement of radioactive materials and, therefore, to meet the general safety objectives. The International Thermonuclear Experimental Reactor-Fusion Power Shutdown System (ITER-FPSS) was the system selected for the application because of its fusion-specific character. The performed application substantially confirms the level of safety importance classification (SIC) assigned to the FPSS by the ITER team (SIC level 3). A set of safety requirements, concerning aspects of reliability and performance, has been defined for the FPSS. These requirements integrate and specify, for the FPSS, the generic implications currently imposed by the ITER team on the safety systems classified SIC-3. Some FPSS design specifications are also suggested to address the burden of proof requested to justify that its safety requirements can be met by the design and can be maintained over the life-time of ITER.
Keywords
Fusion-specific system , Plant safety architecture , Gas-injection system
Journal title
Fusion Engineering and Design
Serial Year
2001
Journal title
Fusion Engineering and Design
Record number
2351232
Link To Document