• Title of article

    Design of cryosorption pumps for TEST BEDS of ITER relevant Neutral Beam Injectors

  • Author/Authors

    Dremel، نويسنده , , M. and Day، نويسنده , , C. and Mack، نويسنده , , A. and Jensen، نويسنده , , H. and Speth، نويسنده , , E. and Falter، نويسنده , , H.D. and Riedl، نويسنده , , R. and Cordier، نويسنده , , J.J. and Gravil، نويسنده , , B. I. Henry، نويسنده , , D. and Zaccaria، نويسنده , , P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    5
  • From page
    205
  • To page
    209
  • Abstract
    This paper presents the results of the design investigations and the manufacturing of cryosorption pumps for the Neutral Beam Test Facility ‘MANITU’ at Max Planck Institute for Plasma Physics (IPP) and the cryopump design analyses performed for the development of a test facility for the first ITER Neutral Beam Injector. o identical cryopumps for IPP are foreseen to pump a hydrogen-throughput of 3 Pa m3/s (H2) with a pumping speed of 350 m3/s per pump. The pressure conditions must be maintained over 4 h pumping without regeneration of the cryopanels. For the ITER Neutral Beam Test Facility, design calculations to assess heat loads and pumping parameters of the cryopumps will be briefly described.
  • Keywords
    Cryosorption , Heat load , Neutral beam injector , Cryopump
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2005
  • Journal title
    Fusion Engineering and Design
  • Record number