• Title of article

    Thermal analysis and Ohmic loss estimation of polarizer for ITER ECCD system

  • Author/Authors

    Saigusa، نويسنده , , M. and Takahashi، نويسنده , , K. and Kashiwa، نويسنده , , Y. and Oishi، نويسنده , , S. and Hoshi، نويسنده , , Y. and Nakahata، نويسنده , , H. and Kasugai، نويسنده , , Anatoly A. and Sakamoto، نويسنده , , K. and Imai، نويسنده , , T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    6
  • From page
    473
  • To page
    478
  • Abstract
    A high power polarizer using a single grooved mirror has been developed for an electron cyclotron current drive (ECCD) system of the International Thermonuclear Experimental Reactor (ITER). Two grooved mirrors were tested at a frequency of 170 GHz, rf power of 441 kW and a pulse duration of 0.1–6 s for estimating Ohmic losses. The Ohmic loss of grooved mirror strongly depends not only on the rotation angle of the polarization plane of the incident waves, but also on the mirror rotaion angle. The thermal analysis of the grooved mirror has been performed with the 3D FEM code: FEVA.
  • Keywords
    ITER ECCD system , polarizer , Ohmic losses , Grooved mirror , Polarization
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2005
  • Journal title
    Fusion Engineering and Design
  • Record number

    2352199