• Title of article

    Tore-Supra infrared thermography system, a real steady-state diagnostic

  • Author/Authors

    Guilhem، نويسنده , , D. and Bondil، نويسنده , , J.L. and Bertrand، نويسنده , , B. and Desgranges، نويسنده , , C. and Lipa، نويسنده , , M. and Messina، نويسنده , , P. and Missirlian، نويسنده , , M. and Portafaix، نويسنده , , C. and Reichle، نويسنده , , R. and Roche، نويسنده , , H. and Saille، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    5
  • From page
    879
  • To page
    883
  • Abstract
    Tore-Supra Tokamak (Ip = 1.5 MA, Bt = 4 T) has been constructed with a steady-state magnetic field using super-conducting magnets and water-cooled plasma facing components (PFCs) for high-performance long pulse plasma discharges. When not actively cooled, plasma facing components can only accumulate a limited amount of energy since the temperature increases continuously during the discharge until radiation cooling equals the incoming heat flux. Such an environment is found in the JET Tokamak [JET Team, IAEA-CN-60/A1–3, Seville, 1994] and on TRIAM [M. Sakamoto, H. Nakashima, S. Kawasaki, A. Iyomasa, S.V. Kulkarni, M. Hasegawa, E. Jotaki, H. Zushi, K. Nakamura, K. Hanada, S. Itoh, Static and dynamic properties of wall recycling in TRIAM-1M, J. Nucl. Mater. 313–316 (2003) 519–523] [Y. Kamada, et al., Nucl. Fusion 3 (1999) 1845]. In Tore-Supra, the surface temperature of the actively cooled plasma facing components reach steady state within a second. We present here the Tore-Supra thermographic system, made of seven endoscope bodies equipped so far with eight infrared (IR) cameras. It has to be noted that this diagnostic is the first diagnostic to be actively cooled, as required for steady state. The main purpose of such a diagnostic is to prevent the plasma to damage the actively cooled plasma facing components (ACPFCs), which consist of the toroidal pumped limiter (TPL), 7 m2, and of five radio-frequency antennae, 1.5 m2 each.
  • Keywords
    Steady-state diagnostic , Infrared thermography , Long pulse operation
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2005
  • Journal title
    Fusion Engineering and Design
  • Record number

    2352525