Title of article :
Acceptance criteria for the ITER divertor vertical target
Author/Authors :
Fouquet، نويسنده , , S. and Schlosser، نويسنده , , J. and Merola، نويسنده , , M. and Durocher، نويسنده , , A. and Escourbiac، نويسنده , , F. and Grosman، نويسنده , , A. and Missirlian، نويسنده , , M. and Portafaix، نويسنده , , C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
In the frame of the toroidal pump limiter fabrication for Tore Supra, CEA developed a large experience of infrared test for acceptance of high heat flux components armoured with carbon fibre composite flat tiles. The test is based on a thermal transient induced by an alternative hot/cold water flow in the heat sink structure. The tile surface temperature transients are compared with those of a reference element, the maximum difference for each tile leading to a value called ΔTref_max. This method is proposed for the commissioning of plasma facing components for the ITER divertor vertical target. This paper describes the determination of the best acceptance criteria for the “monoblock” geometry of the carbon part. First, it has been shown that the location and the extension of the defects could reliably be determined by monitoring both top and lateral surfaces during the test. Second, it was possible to fix an acceptance method based on ΔTref_max. Samples with calibrated defects are now under fabrication to validate the results.
Keywords :
Infrared thermography , Acceptance criteria , Plasma facing components , ITER divertor
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design