Abstract :
A Monte Carlo procedure has been applied in this work in order to address the impact of activation cross-sections (XS) uncertainties on contact dose rate and decay heat calculations for the outboard first wall (FW) of a magnetic fusion energy (MFE) demonstration (DEMO) reactor. The XSs inducing the major uncertainty in the prediction of activation related quantities have been identified. Results have shown that for times corresponding to maintenance activities the uncertainties effect is insignificant since the dominant XSs involved in these calculations are based on accurate experimental data evaluations. However, for times corresponding to waste management/recycling activities, the errors induced by the XSs uncertainties, which in this case are evaluated using systematic models, must be considered. It has been found that two particular isotopes, 60Co and 94Nb, are key contributors to the global DEMO FW activation uncertainty results. In these cases, the benefit from further improvements in the accuracy of the critical reaction XSs is discussed.
Keywords :
Demo , Activation cross-section , uncertainty analysis
Journal title :
Fusion Engineering and Design
Serial Year :
2006
Journal title :
Fusion Engineering and Design
Record number :
2353187
Link To Document :
بازگشت