• Title of article

    Development review of transient recorders with onboard isolation on JET

  • Author/Authors

    Jennison، نويسنده , , M. and Alper، نويسنده , , B. and Dorling، نويسنده , , S. and Fullard، نويسنده , , K. and Horton، نويسنده , , A. and Lucock، نويسنده , , R. and Perry، نويسنده , , C. and Thomas، نويسنده , , P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    6
  • From page
    1879
  • To page
    1884
  • Abstract
    The JET tokamak is currently using about 7000 transient recorder channels for data acquisition, mainly sampling at 5 kHz but including a few at 1 MHz or higher. Nearly half of the channels are provided by module designs with front ends that are galvanically isolated to over 1000 V. Performing analogue-to-digital conversion before isolation provides many benefits. This paper reviews three such designs that have been commissioned or developed by control and data acquisition systems (CODAS) personnel over the past 10 years and examines the trends.
  • Keywords
    Transient recorder , ISOLATED , ADC , DAQ
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2006
  • Journal title
    Fusion Engineering and Design
  • Record number