• Title of article

    Arc security system based on harmonics detection for the Tore Supra ICRH transmitter

  • Author/Authors

    Berger-By، نويسنده , , G. and Beaumont، نويسنده , , B. and Lombard، نويسنده , , G. and Millon، نويسنده , , L. and Mollard، نويسنده , , P. and Volpe، نويسنده , , D.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    7
  • From page
    716
  • To page
    722
  • Abstract
    Since 1999 and with the help of Institut fur Plasmaphysik (IPP) Garching, we have tested in the Tore Supra (TS) Ion Cyclotron Resonance Heating (ICRH) transmitter, arc security systems based on harmonics detection in a frequency band lower than the generator frequency. systems have some advantages in comparison with traditional protection systems, which are based on use of a level on the Vr/Vf (reflected to forward voltage ratio) calculation. After some checking for adjustment, they do not use calculation, calibration with frequency or level. They can use RF signals from directional couplers or probes, so they are fully independent of the measurement systems. The detection bandwidth is independent of the antennae working frequencies. In TS the detection principle is insensitive to the cross talk between the antennae and to the antennae coupling variations. In 2001, we have built three systems based on our prototype in order to improve the protection of the three ICRH antennae Q1, Q2 and Q5. The RF principle used on TS ICRH transmitter is described. sults in the last 4 years on an ICRH transmitter module feeding a TS antenna are summarized and some examples typical signals are given.
  • Keywords
    PLASMA , RF safety , ICRH , Arc detection
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2007
  • Journal title
    Fusion Engineering and Design
  • Record number

    2353656