Title of article :
Critical issues of HV dc vacuum and pressurized gas environments for the ITER NB injector
Author/Authors :
Masiello، نويسنده , , A. and De Lorenzi، نويسنده , , A. and Grando، نويسنده , , L. and Svensson، نويسنده , , L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
819
To page :
828
Abstract :
The design of the ITER NB injector involves challenging problems related to the high voltage (HV) dc insulations, which is realized with different media, such as pressurized gas and vacuum either with or without solid insulators. For each type of insulation different physical models have to be used for the design of the components, because different mechanism can lead to a breakdown. s paper all the recognised critical issues for the reliability of the injector HV insulation are described. We are also reporting on the literature studies and the closely related experimental observations and results of the SINGAP test bed injector. Moreover results of finite element (FE) models which simulate the insulating system of the 1 MV bushing, taking into account different HV dc regimes, are presented.
Keywords :
Vacuum insulation , High Voltage , Gas insulation , NB injector
Journal title :
Fusion Engineering and Design
Serial Year :
2007
Journal title :
Fusion Engineering and Design
Record number :
2353696
Link To Document :
بازگشت