• Title of article

    A simple method for designing efficient public lighting, based on new parameter relationships

  • Author/Authors

    Rabaza، نويسنده , , O. and Peٌa-Garcيa، نويسنده , , A. and Pérez-Ocَn، نويسنده , , F. and Gَmez-Lorente، نويسنده , , D.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    11
  • From page
    7305
  • To page
    7315
  • Abstract
    New parameter relationships for public lighting design (i.e. average illuminance, luminaire spacing, and mounting height) were calculated from a large sample of data sets optimized with a multi-objective evolutionary algorithm. Optimization criteria included maximum energy efficiency and overall uniformity. The relations thus derived are a simple and elegant method for designing any type of public lighting installation without the need to use complex, expensive and/or unavailable software. It would therefore be desirable that manufacturers include such parameters in the product datasheet in order to make the calculation easier.
  • Keywords
    Illuminance uniformity , Public lighting , Energy efficiency , Evolutionary algorithms , Average illuminance