• Title of article

    Safety design of radiation shielding for JT-60SA

  • Author/Authors

    Sukegawa، نويسنده , , A.M. and Sakurai، نويسنده , , S. and Masaki، نويسنده , , K. and Kizu، نويسنده , , K. and Tsuchiya، نويسنده , , K. and Shibama، نويسنده , , Y.K. and Hayashi، نويسنده , , T. and Tamai، نويسنده , , H. and Matsukawa، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    2799
  • To page
    2804
  • Abstract
    The radiation shielding, nuclear heating, absorbed dose of the insulator and dose rate have been evaluated for the superconducting tokamak JT-60SA. The shielding structure consists of double wall using the 24 mm thickness of SS316L filled with the 140 mm thickness of borated water (40 °C, 95% 10B enriched). The maximum nuclear heating of the winding at the inboard side of the superconducting TF coil was suppressed to be lower than 0.3 mW/cc. The absorbed dose of the insulator on the in-vessel coil was estimated to be 8.5 MGy for 10 years. The insulators are not necessary to be exchanged with 10 years operation on JT-60SA. The dose rate of JT-60SA site boundary is estimated to be 144 μSv/3 months, and it satisfies the legal limit of 250 μSv/3 months without any additional shielding performance for the JT-60 building.
  • Keywords
    Radiation shielding , JT-60SA , Nuclear heating , Dose rate , Absorbed Dose , Insulator , Vacuum vessel structure
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2007
  • Journal title
    Fusion Engineering and Design
  • Record number