    The MK III actively cooled duct liner for the JET neutral beam line: Thermo-mechanical performance and lifetime estimation

  • Author/Authors

    Li-Puma، نويسنده , , A. and Jones، نويسنده , , T.T.C. and Krivchenkov، نويسنده , , Y. and Martin، نويسنده , , D. and Surrey، نويسنده , , E. and Wilson، نويسنده , , D.J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    7
  • From page
    1142
  • To page
    1148
  • Abstract
    This paper describes the analyses performed to investigate and validate the proposed design for the updated JET MKIII duct side liner, which will replace the present inertial cooled one in the frame of the EP2 neutral beam enhancement project. ermal-hydraulic and thermo-mechanical performance of a duct linerʹs generic module, under various loading scenarios has been assessed. Due to difference in scale between a generic liner module length and the relevant load bearing section thickness (∼1.2 m against 4 mm) two different scale FE models have been assessed, the first ones to evaluate the overall reactions and displacements and the others to calculate concentrated stresses in the most loaded sections. mity to ITER design criteria has been verified for both monotonic and cyclic loads. The effects of fatigue have been considered and an operational life of 8.5 years is predicted for the liner.
  • Keywords
    Generalized plain strain , Sub-modelling , Duct liner , Hypervapotron , Fatigue , Mean stress
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2008
  • Journal title
    Fusion Engineering and Design
  • Record number