Title of article :
ITER blanket module shield block design and analysis
Author/Authors :
Mitin، نويسنده , , D. and Khomyakov، نويسنده , , S. and Razmerov، نويسنده , , A. and Strebkov، نويسنده , , Yu.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
11
From page :
1188
To page :
1198
Abstract :
This paper presents the alternative design of the shield block cooling path for a typical ITER blanket module with a predominantly sequential flow circuit. A number of serious disadvantages have been observed for the reference design, where the parallel flow circuit is used, which is inherent in the majority of blanket modules. The paper discusses these disadvantages and demonstrates the benefit of the alternative design based on the detailed design and the technological, hydraulic, thermal, structural and strength analyses, conducted for module #17.
Keywords :
ITER , Blanket , Cooling path , Shield block
Journal title :
Fusion Engineering and Design
Serial Year :
2008
Journal title :
Fusion Engineering and Design
Record number :
2355040
Link To Document :
بازگشت