• Title of article

    Measurement of tritium permeation in flibe (2LiF–BeF2)

  • Author/Authors

    Calderoni، نويسنده , , P. and Sharpe، نويسنده , , P. and Hara، نويسنده , , M. de Oya، نويسنده , , Y.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    4
  • From page
    1331
  • To page
    1334
  • Abstract
    This paper reports on the experimental investigation of tritium permeation in flibe (2LiF–BeF2) at the Safety and Tritium Applied Research facility of the Idaho National Laboratory. A stainless steel cell formed by two independent volumes separated by a 2-mm thick nickel membrane is maintained at temperatures between 500 and 700 °C. A controlled amount of T2 gas is flown in excess of argon in the source volume in contact with the bottom side of the nickel membrane, while a layer of molten salt is in contact with the top side. The tritium permeating above the liquid surface is carried by an argon flow to a diagnostic system comprised of a quadrupole mass spectrometer, a gas chromatographer and a proportional counter. Tritium permeability in flibe as a function of temperature is determined by the measured permeation flow rates reached in steady-state conditions, while the diffusivity is determined by fitting the transient process with the analytical solution for the diffusion process. As a result, the solubility of tritium in flibe as a function of temperature is also determined.
  • Keywords
    Fusion , tritium , Molten salt , solubility , Diffusivity
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2008
  • Journal title
    Fusion Engineering and Design
  • Record number

    2355097