Title of article
Infrared thermography inspection of the ITER vertical target qualification prototypes manufactured by European industry using SATIR
Author/Authors
Durocher، نويسنده , , A. and Escourbiac، نويسنده , , F. and Richou، نويسنده , , M. and Vignal، نويسنده , , N. and Merola، نويسنده , , M. and Riccardi، نويسنده , , B. and Cantone، نويسنده , , V. and Constans، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
5
From page
314
To page
318
Abstract
High heat flux loaded components which will be installed in the ITER Divertor require a heat flux removal capability in the range 5–10 MW/m2 at steady-state and up to 20 MW/m2 in transients. Within the ITER plasma facing components procurement context, each party should demonstrate its technical capability to carry out the manufacturing with the required quality. This is achieved through the successful manufacturing and testing of medium-size qualification prototypes. Each Qualification Prototype consists of three high heat flux units mounted onto an actively cooled supporting structure. Currently, the SATIR method has been identified by the ITER Organization as the basic test to decide upon the final acceptance of the ITER Divertor components. SATIR testing was performed on each CFC part of European HHF units prior to the insertion of the twisted tape and prior to assembling the units onto the steel support structure. The paper deals with SATIR results of all qualification prototypes manufactured by European industry.
Keywords
ITER divertor , Plasma facing component , SATIR test bed
Journal title
Fusion Engineering and Design
Serial Year
2009
Journal title
Fusion Engineering and Design
Record number
2355572
Link To Document