Title of article :
Mechanical testing of a FW panel attachment system for ITER
Author/Authors :
Oliva، نويسنده , , Vladislav and V?clav?k، نويسنده , , Jaroslav and Materna، نويسنده , , Ale? and Lorenzetto، نويسنده , , Patrick and Furmanek، نويسنده , , Andreas، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
An objective of experiments and finite element simulations was to check the stiffness, the strength and the fatigue resistance of the attachment of the First Wall panels onto a shield block of blanket modules according to the ITER 2001 design. The panel has a poloidal key at the rear side (in so-called option A with the rear access bolting) and it is attached by means of special studs located on a key-way in the shield block. Special device for a test of stud tensile pre-load relaxation during a thermal cycling was developed. True-to-scale panels, the shield block mock-up and simplified studs were fabricated and the assembly was loaded alternatively by radial moment, poloidal force or poloidal moment simulating the loading during off-normal plasma operations. Thermal cycling led to an acceptable stud pre-load relaxation. Mechanical cycling caused neither the pre-load relaxation nor the loss of the contact in the key-way nor a damage of the attachment system. The combination of poloidal moment and radial force during vertical displacement events (VDEs) seems to be a most dangerous case because it could lead to the loss of the key–key-way contact.
Keywords :
Mechanical structures in vessel , First wall , Panel attachment system , ITER
Journal title :
Fusion Engineering and Design
Journal title :