Saito، نويسنده , , K. and Kasahara، نويسنده , , H. and Seki، نويسنده , , T. and Kumazawa، نويسنده , , R. and Mutoh، نويسنده , , T. and Watanabe، نويسنده , , T. and Shimpo، نويسنده , , F. and Nomura، نويسنده , , G. and Osakabe، نويسنده , , M. and Ichimura، نويسنده , , M. and Higaki، نويسنده , , H. Kiyomi Komori، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
4
From page
1676
To page
1679
Abstract
Ion cyclotron emissions (ICEs) were clearly detected in the Large Helical Device (LHD) during perpendicular neutral beam (NB) injection. Antennas for the ion cyclotron range of frequencies (ICRF) heating were used as probes. The frequencies of ICEs were proportional to magnetic field strength. The location of ICE excitation was a peripheral region of plasma and the source particles were lost-ions injected by the perpendicular NB.