Kavousfar، Saeed نويسنده Islamic Azad University, Science and Research Branch , , Esmaeilzadeh، Esmaeil نويسنده Tabriz University, Tabriz, Iran , , mahdavy moghaddam، hossein نويسنده IAU , , Pouryoussefi، Sohrab Gholamhosein نويسنده K.N. Toosi University of Technology, Tehran, Iran , , Mirzaei، Masoud نويسنده Department of Chemistry, Ferdowsi University of Mashhad, P.O. Box 91779-1436 Mashhad, I.R. IRAN ,
Issue Information :
فصلنامه با شماره پیاپی 27 سال 2016
Abstract :
In this paper, the air flow around a blunt flat plate with a rounded leading edge has been experimentally
examined with and without the presence of a plasma actuator. Tests have been conducted with Reynolds
numbers ranging from 104 to 105. Significant phenomena in this flow field is the flow separation at the
leading edge of the body, which called separation bubble. There are two considerably dimensionless
parameters in this experiment. One of them is the leading edge radius ratio to body thickness and other one is
the ratio of maximum velocity induced by plasma actuator to free stream velocity. Geometries with the values
of R/D=0, 1/16, 2/16, 4/16 were tested. For each geometry, the effectiveness of plasma actuator on the
separation bubble is studied in different values of velocity ratio. The results show that, the effect of plasma
actuator for the geometry with sharp edge (R/D=0), is negligible, while in geometry with rounded edge, the
plasma actuator has significant effect on the separation bubble domain. This effectiveness is enhanced, by
increasing of leading edge radius and velocity ratio, so that in rounded edge geometry (R/D=4/16) length of
separation bubble is reduced about 75%.