Title of article :
Experiment and analysis of hypervapotron mock-ups for preparing the 2nd qualification of the ITER blanket first wall
Author/Authors :
Lee، نويسنده , , Dong Won and Bae، نويسنده , , Young Dug and Kim، نويسنده , , Suk Kwon and Bang، نويسنده , , In Cheol، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
2155
To page :
2159
Abstract :
According to the increased heat flux condition up to 5 MW/m2 in the International Thermonuclear Experimental Reactor (ITER), new design of the blanket first wall (FW) has been considered and the analysis was performed with ANSYS-CFX for checking its temperature with the ITER operation conditions. And a semi-prototype of the FW was proposed to be tested with the similar heat flux conditions under the second qualification for the FW procurement. In order to investigate the fabrication procedure and analysis capability of the code, two types of mock-up were fabricated according to the current semi-prototype design except for bending shape; one with hypervapotron and another without it. They were tested with KoHLT-2 (Korea Heat Load Test) facility and the results were compared with the ones by CFX code. The mass flow rate of inlet coolant was the same as the ITER condition and heat flux was loaded up to 0.48 MW/m2 heat flux. The results show that the temperature of the mock-up can be predicted using the CFX code even with the complex geometry and the hypervapotron shows its function to increase the cooling.
Keywords :
Hypervapotron , KoHLT , ITER blanket first wall , ANSYS-CFX
Journal title :
Fusion Engineering and Design
Serial Year :
2010
Journal title :
Fusion Engineering and Design
Record number :
2357258
Link To Document :
بازگشت