Title of article
Current phase control test based on real-time measurement of impedance matrix of ICRF antennas
Author/Authors
Saito، نويسنده , , K. and Kumazawa، نويسنده , , R. and Seki، نويسنده , , T. and Kasahara، نويسنده , , H. and Yokota، نويسنده , , M. and Nomura، نويسنده , , G. and Shimpo، نويسنده , , F. and Mutoh، نويسنده , , T.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
5
From page
987
To page
991
Abstract
New ion cyclotron range of frequencies (ICRF) antennas have just been installed in the large helical device (LHD). These side-by-side ICRF antennas are symmetrical and designed to launch fast waves with various wave numbers parallel to the magnetic field line. The wave number can be controlled by changing the current phase on the straps; however, the mutual coupling between antennas changes antenna impedances, even if the plasma parameters are constant, leading to an increase in the reflected power. In addition to the current phase control, impedance matching devices must be tuned for the protection of tetrode tubes and efficient power injection. For this purpose, the impedance matrix of ICRF antennas must be determined, and it can be deduced from the forward and reflected waves at the outlet of the power amplifier by assuming geometric symmetry and reciprocity of the antennas. Using half-scale antennas, we successfully demonstrated simultaneous impedance matching and current phase control.
Keywords
LHD , Mutual Coupling , Phase control , Impedance Matching , ICRF antenna
Journal title
Fusion Engineering and Design
Serial Year
2011
Journal title
Fusion Engineering and Design
Record number
2357910
Link To Document