Title of article :
Design of the ITER high-frequency magnetic diagnostic coils
Author/Authors :
Toussaint، نويسنده , , M. and Testa، نويسنده , , D. and Baluc، نويسنده , , N. and Chavan، نويسنده , , R. and Fournier، نويسنده , , Y. and Lister، نويسنده , , J.B. and Maeder، نويسنده , , T. and Marmillod، نويسنده , , P. and Sanchez، نويسنده , , F. and Stِck، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
This paper is an overview of work carried out on the design of the ITER high-frequency magnetic diagnostic coil (HF sensor). In the first part, the ITER requirements for the HF sensor are presented. In the second part, the ITER reference design of the HF sensor has been assessed and showed some potential weaknesses, which led us to the conclusion that alternative designs could usefully be examined. Several options have been explored, and are presented in the third part: (a) direct laser cutting a metallic tube, (b) stacking of plane windings manufactured from a tungsten plate by electrical discharge machining, (c) coil using the conventional spring manufacture. In the fourth part, sensors using the low temperature co-fired ceramic technology (LTCC) are presented: (d) monolithic 1D magnetic flux sensors based on LTCC technology, and (e) monolithic 3D magnetic flux sensors based on the same LTCC technology. The solution which showed the best results is the monolithic 3D magnetic flux sensor based on LTCC.
Keywords :
ITER , High-frequency , In-vessel , LTCC , Sensor , COIL
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design