Title of article
Operating experience review of tritium-in-water monitors
Author/Authors
Bruyere، نويسنده , , Susan A. and Cadwallader، نويسنده , , Lee C.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
4
From page
565
To page
568
Abstract
Monitoring tritium facility and fusion experiment effluent streams is an environmental safety requirement. This paper presents data on the operating experience of a solid scintillant monitor for tritium in effluent water. Operating experiences were used to calculate an average monitor failure rate of 4E−05/h for failure to function. Maintenance experiences were examined to find the active repair time for this type of monitor, which varied from 22 min for filter replacement to 11 days of downtime while waiting for spare parts to arrive on site. These data support planning for monitor use; the number of monitors needed, allocating technician time for maintenance, inventories of spare parts, and other issues.
Keywords
Tritium monitoring , Scintillation counting , Reliability , maintainability
Journal title
Fusion Engineering and Design
Serial Year
2012
Journal title
Fusion Engineering and Design
Record number
2359356
Link To Document