Title of article :
Monte Carlo calculation of the thermal radiation heat load of the ITER pre-production cryopump
Author/Authors :
Luo، نويسنده , , Xueli and Hauer، نويسنده , , Volker and Day، نويسنده , , Christian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
Large-scale customized cryogenic pumps are employed to pump the ITER torus. The high performance of this kind of non-conventional cryopumps is achieved by the cryosorption of the gas load on the charcoal-coated panels working at 4.5 K. In order to avoid the direct thermal radiation, the 4.5 K pumping panels are installed inside a 80 K heat shielding system. In this paper, we will present the Monte Carlo simulation of the thermal radiation heat loads to the cryopanel circuit, the thermal shield circuit and the valve head when the pump is in stand-by, pumping and regeneration. The results are of great importance in the design of the ITER pre-production cryopump (PPC).
Keywords :
ITER , Thermal radiation heat load , Monte Carlo simulation , Cryogenic pump
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design