Title of article :
Electromagnetic analysis of ITER diagnostic equatorial port plugs during plasma disruptions
Author/Authors :
Zhai، نويسنده , , Y. and Feder، نويسنده , , R. and Brooks، نويسنده , , A. and Ulrickson، نويسنده , , M. C. Pitcher and M. R. Jacyna، نويسنده , , C.S. and Loesser، نويسنده , , G.D.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
4
From page :
547
To page :
550
Abstract :
ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the diagnostic first walls (DFWs), diagnostic shield modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.
Keywords :
ITER diagnostic engineering , Electromagnetic analysis , Diagnostic port plugs , Plasma disruptions
Journal title :
Fusion Engineering and Design
Serial Year :
2013
Journal title :
Fusion Engineering and Design
Record number :
2360786
Link To Document :
بازگشت