• Title of article

    Results and consequences of high heat flux testing as quality assessment of the Wendelstein 7-X divertor

  • Author/Authors

    Greuner، نويسنده , , Henri and Toussaint، نويسنده , , Udo v. and Bِswirth، نويسنده , , Bernd and Boscary، نويسنده , , Jean and Peacock، نويسنده , , Alan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    4
  • From page
    581
  • To page
    584
  • Abstract
    The series manufacturing of the first 282 Wendelstein 7-X divertor elements was concluded in 2011. The divertor is designed to remove a steady-state heat load of 10 MW/m2. 940 target elements of five different types made of CuCrZr heat sinks and covered with 16,000 CFC NB31 flat-tiles have to be produced. Additional to quality assessment during the manufacturing process, a final assessment of the delivered elements with operational heat load is indispensable to ensure a constant high thermal performance of the installed divertor. on the results of the pre-series testing a statistical quality assessment method has been developed for the series production. The application of this method to the series elements ensures their thermal performance with reasonable high heat flux test effort.
  • Keywords
    W7-X , Plasma-facing components , statistics , High heat flux tests , Six-sigma , Divertor
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2013
  • Journal title
    Fusion Engineering and Design
  • Record number

    2360810