Title of article
KATHELO: A new high heat flux component testing facility
Author/Authors
Ghidersa، نويسنده , , B.E. and Jin، نويسنده , , X. and Rieth، نويسنده , , M. and Ionescu-Bujor، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
4
From page
854
To page
857
Abstract
In this article a new helium cooled test facility is presented. The loop, KATHELO, is designed to operate at pressures up to 10 MPa and temperatures up to 800 °C in order to be able to provide suitable testing conditions for the helium cooled divertor concept developed at KIT. The general layout of the loop is introduced and the some of the technological solutions adopted for the loop components are discussed. The thermal-dynamic behavior of the loop during start-up and steady state operation for two different scenarios is analyzed using a RELAP-3D model of the circuit. Based on these simulations the heating power needed for high temperature operation is estimated. A particular attention is given to the thermal coupling between the cold and hot leg of the loop with emphasis on overall loop efficiency.
Keywords
Demo , Divertor , RELAP , Helium cooling , High heat flux facility
Journal title
Fusion Engineering and Design
Serial Year
2013
Journal title
Fusion Engineering and Design
Record number
2360982
Link To Document