Title of article :
Engineering aspects of a fully mirrored endoscope
Author/Authors :
Terra، نويسنده , , A. and Huber، نويسنده , , A. and Schweer، نويسنده , , B. and Mertens، نويسنده , , Ph. and Arnoux، نويسنده , , G. and Balshaw، نويسنده , , N. and Brezinsek، نويسنده , , S. and Egner، نويسنده , , S. and Hartl، نويسنده , , M. and Kampf، نويسنده , , D. and Klammer، نويسنده , , J. and Lambertz، نويسنده , , H.T. and Morlock، نويسنده , , C. and Murari، نويسنده , , A. and Reindl، نويسنده , , M. and Sanders، نويسنده , , S. A. Sergienko، نويسنده , , G. and Spencer، نويسنده , , G. and Samm، نويسنده , , U. and Zauner، نويسنده , , C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
5
From page :
1400
To page :
1404
Abstract :
The development of optical diagnostics, like endoscopes, compatible with the ITER environment (metallic plasma facing components, neutron proof optics, etc.) is a challenge, but current tokamaks such as JET provide opportunities to test fully working concepts. This paper describes the engineering aspects of a fully mirrored endoscope that has recently been designed, procured and installed on JET. The system must operate in a very strict environment with high temperature, high magnetic fields up to B = 4 T and rapid field variations (∂B/∂t ∼ 100 T/s) that induce high stresses due to eddy currents in the front mirror assembly. It must be designed to withstand high mechanical loads especially during disruptions, which lead to acceleration of about 7 g at 14 Hz. For the JET endoscope, when the plasma thermal loading, direct and indirect, was added to the assumed disruption loads, the reserve factor, defined as a ratio of yield strength over summed up von Mises stresses, was close to 1 for the mirror components. To ensure reliable operation, several analyses were performed to evaluate the thermo-mechanical performance of the endoscope and a final validation was obtained from mechanical and thermal tests, before the systemʹs final installation in May 2011. During the tests, stability of the field of view angle variation was kept below 1° despite the high thermal gradient on endoscope head (∂T/∂x ∼ 500 K/m). In parallel, to ensure long time operation and to prevent undesirable performance degradation, a shutter system was also implemented in order to reduce impurity deposition on in-vessel mirrors but also to allow in situ transmission calibration. One of the main specifications of the shutter system was high reliability. This was considered as achieved when the prototype was successfully tested to 3000 cycles at a temperature of 300 °C.
Keywords :
Plasma facing material , optics , Endoscope , ENGINEERING
Journal title :
Fusion Engineering and Design
Serial Year :
2013
Journal title :
Fusion Engineering and Design
Record number :
2361359
Link To Document :
بازگشت