Title of article :
Calibration procedure for plasma polarimetry based on the complex amplitude ratio measurements
Author/Authors :
Bieg، نويسنده , , Bohdan and Kravtsov، نويسنده , , Yury A. and Cieplik، نويسنده , , Marek، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
3
From page :
1452
To page :
1454
Abstract :
New methodology for plasma polarimeters calibration is suggested, based on the complex amplitude ratio (CAR) measurements. This methodology reduces calibration to determination of three complex parameters of transfer matrix, characterizing polarization changes in optical system. Having obtained transfer matrix, full characteristic of the optic system could be obtained: eigenstates, phase shift and relative attenuation of the slow and fast wave. Polarization state of the sounding electromagnetic wave after the plasma is determined from the measured complex amplitude ratio by simple inversion of transfer matrix. Calibration procedure under discussion is simpler, more transparent and reliable than traditional procedures, using Stokes vector technique or angular parameters of polarization ellipse.
Keywords :
Plasma polarimetry , Calibration , Complex amplitude ratio