• Title of article

    Paschen testing of ITER prototype cryogenic axial breaks

  • Author/Authors

    Fink، نويسنده , , S. and Fietz، نويسنده , , W.H. and Kraft، نويسنده , , Dennis G. and Scheller، نويسنده , , H. and Urbach، نويسنده , , E. and Zwecker، نويسنده , , V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    3
  • From page
    1475
  • To page
    1477
  • Abstract
    Axial insulation breaks are needed in forced cooled cryogenic high voltage devices for the separation of the high voltage area from the grounded pipe system. The ITER cryogenic axial breaks will be surrounded by good vacuum in case of normal operation but also under vacuum breakdown conditions sufficient dielectric strength is required for a reliable fast discharge of the coil system. A Paschen tight design of the ITER prototype breaks enables high voltage operation independent on the outer vacuum or gas conditions. Consecutively two pretested ITER prototype breaks were integrated in the insulation system of a Paschen test unit and high voltage tested. Two different ways to perform the Paschen testing were used for both breaks. The preparation of the breaks and the test setup are described and the test results are given.
  • Keywords
    Electrical insulation , High Voltage , ITER , Superconducting coil
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2013
  • Journal title
    Fusion Engineering and Design
  • Record number

    2361408