Title of article :
Cryogenic mechanical testing of ITER prototype axial breaks
Author/Authors :
Weiss، نويسنده , , Klaus-Peter and Urbach، نويسنده , , Elisabeth and Kraft، نويسنده , , Günter and Scheller، نويسنده , , Holger، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
4
From page :
1533
To page :
1536
Abstract :
Within the superconducting magnet program for ITER, cryogenic components need to be tested to verify their design. Especially for the helium supply of the magnet system, feeders are needed integrating at the same time high voltage insulation to separate the inner magnet system electrically from the outer cryostat shell. Beside of high voltage and helium flow properties, these axial breaks will be exposed to a limited mechanical loading during operation of the magnet system. Therefore, mechanical tests needs to be performed at room temperature as well as at cryogenic temperature of 77 K. ible breaker design was provided by Babcock Noell. To verify this design mechanically quasi-static and fatigue tests under bending, torsion and axial loading were done. Results on the performance of the prototypes are presented approving a superior mechanical quality.
Keywords :
mechanical properties , ITER , Superconducting coil , Electrical insulation