Title of article :
Design and testing of secondary mirrors for the core CXRS diagnostic system in ITER
Author/Authors :
Krimmer، نويسنده , , A. and Kassek، نويسنده , , G. and Allelein، نويسنده , , H.J. and Krasikov، نويسنده , , Yu. and Neubauer، نويسنده , , O.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
4
From page :
2021
To page :
2024
Abstract :
The core Charge Exchange Recombination Spectroscopy (core CXRS) diagnostic system for ITER is projected with 7 consecutive in-vacuum mirrors. Based on overall system stability, maintenance and lifetime considerations, ITEr grade Stainless Steel 316L(N) was chosen as first candidate for the substrate of the mirrors two to seven. A robust design with remote handling friendly bolted interface has been devised. It features uniformly distributed internal temperature control with minimal welds. The design, simulation results and plans for a prototype are discussed. s 4–7 are planned with a multilayer dielectric coating at preferably >98% reflectivity. The ability to manufacture such a coating on SS316L(N)-substrate which works reliably under ITER conditions is investigated. A 64 λ/4 layer coating of TiO2 and SiO2 was chosen for initial investigations. Adhesion tests were carried out and testing under ITER-conditions is under preparation. The paper covers the coating, sample manufacturing and status of the testing.
Keywords :
ITER diagnostic system , Core CXRS , Mirror mechanical design , Multilayer dielectric coating
Journal title :
Fusion Engineering and Design
Serial Year :
2013
Journal title :
Fusion Engineering and Design
Record number :
2361757
Link To Document :
بازگشت