Title of article :
Shut-Down Dose Rate analysis for ITER Diagnostic Equatorial and Upper Ports
Author/Authors :
Serikov، نويسنده , , Arkady and Bertalot، نويسنده , , Luciano and Fischer، نويسنده , , Ulrich and Pitcher، نويسنده , , Charles Spencer and Suarez، نويسنده , , Alejandro and Udintsev، نويسنده , , Victor S. and Weinhorst، نويسنده , , Bastian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
1964
To page :
1968
Abstract :
The Shut-Down Dose Rate (SDDR) is an important criterion of radiation safety for the personnel access for maintenance operations in ITER ports after the cessation of the D-T 14 MeV neutron fusion source. Therefore, the problem of the SDDR calculations attracts the attention of fusion neutronics community because SDDR in such a large and geometrically complicated fusion device as the ITER tokamak is challenging to compute. This challenge has been faced and overcome by applying dedicated methodological approaches explained in this paper. The results of the SDDR analysis allowed us to propose several design solutions for improvement of the radiation shielding of the ITER Generic Diagnostic Equatorial and Upper Port Plugs (EPP and UPP). The SDDR analysis was focused on the interspace area located between the ITER bioshield and port plugs where the personnel access is envisaged at ∼12 days after the ITER shut-down. By this analysis the radiation streaming pathways and dominant sources of decay radiation were revealed and the methods to mitigate the streaming and subsequent activation were found. The optimization of the port shielding was targeted on minimization of the SDDR in the interspace area following the ALARA principle and taking into account the feasibility to implement proposed shielding options with the actual hardware. Among them, wrapping the EPP walls with the B4C tiles improves the EPP shielding performance. While void around the ELM/in-vessel coils and blanket manifolds leads to the performance reduction. The SDDR inside the Generic UPP interspace depends mainly on the environment (blanket, manifolds, and gaps).
Keywords :
ITER , Diagnostic Upper Port Plug , Diagnostic Equatorial Port Plug , R2Smesh and D1S methods , Fusion neutronics , Shut-down dose rate
Journal title :
Fusion Engineering and Design
Serial Year :
2014
Journal title :
Fusion Engineering and Design
Record number :
2362869
Link To Document :
بازگشت